- + Command Consoles
- + Data Center Solutions
- + Facility Solutions
- + IT Infrastructure
- + Office Interiors
- + Server Cabinets
- .Cooling Cabinets
- Accessories
- Airflow Management
- Aisle Containment
- Blade Server Cabinet
- Blanking Panels
- by AMCO
- by APC
- by Damac
- by Eaton
- by Electrorack
- by Great Lakes Case
- by Hewlett Packard
- by IBM
- by Kendall Howard
- by Knurr
- by Liebert
- by Lowell
- by Mainline
- by Middle Atlantic
- by NER
- by Ortronics
- by Panduit
- by Rittal
- by SMC
- by Tripplite
- Cabinet Ventilation
- CableTrack Rack
- Co-location Enclosures
- Double Wide Enclosure
- Enclosure Monitoring
- Fiberglass Enclosures
- Home Theater Cabinets
- Installation Tools
- Kiosks
- Military Rated Cabinets
- Multi-Rack II
- Notebook Lockers
- Outdoor Enclosures
- Platinum 42™
- Platinum HDC-(High Density Cable Cabinet)
- Portable Server Cabinets
- Quick Ship Racks
- Rack Cases
- Rack PDU
- Rack Systems
- Rear Door Heat Exchangers
- Relay Racks- 4-Post
- Rittal Express
- Secure Rack
- Security Cabinet
- Seismic Cabinets
- Server Lifts
- Smart Bunker-I
- Smart Bunker-II
- Smart Cabinet
- SMC Premier Enclosure
- Specialty Cabinets
- Stainless Steel
- Sub-Floor Bases
- Under Counter Cabinets
- Wall Cabinets
- Wireless Enclosure
- + Technical Furniture
- + Technical Products
- + Desktops & Servers
- + Monitors
- + Networking Products
- + Notebooks
- + Printers
- + Software
- + Storage Solutions
- + IT MEGASTORE
|
||||||||||||||||
|
Knürr CoolTherm® racks are completely sealed off from the room air. The dissipation of the total power loss is made via an air-to-water heat exchanger in the base area or door of the rack, which is connected to the cold water system in the building. Redundant high-performance fans drive a closed cold air circulation in the rack’s interior. The built-in servers are supplied from the front with air that is brought to the right temperature of about 20–25°C (68 °F to 77 °F). The warmed air is collected at the rear topside in the rack, pushed down by the heat exchanger and back to the front, to the server front panels. There are no requirements for room thermal management; the rack system is fully independent from the room air. The heat exchanger only requires 6 U per rack, which means that in a 46 U rack, 40 U remain for any kind of complete equipping with components. Apart from the heat exchanger, the user will find a perfectly normal 19” server rack. This means that there are absolutely no restrictions for installing components. Everything that can be installed in a conventional rack can also be located without change in the Knürr CoolTherm®.
Total Products: 2 |







































